Two-electrode discharge tube / lightning protection component tester
This instrument adopts a charging function for offline use, overcoming the disadvantage of traditional products that require plug-in power and are inconvenient for on-site operation. The voltage output of 2000V has a wider application range. It features high-voltage short-circuit protection, automatic discharge function, and is reliable, safe, and durable. At the same time, it uses a luxurious large color screen display, data storage, data review, pass/fail judgment, automatic shutdown, USB data upload, and other functions. The whole machine is beautiful and high-grade, with a wide range, high resolution, convenient operation, easy portability, accuracy, reliability, stable performance, and strong anti-interference capability.
It has anti-vibration, dust-proof, and moisture-proof structures, adapting to harsh working environments. It is a common and essential instrument for meteorological lightning protection, electric power, post and telecommunications, communication, mechanical and electrical installation and maintenance, as well as industrial enterprises that use electricity as industrial power or energy. It is suitable for measuring the performance parameters of various lightning arresters and surge protectors.
It is composed of medium and large-scale integrated circuits. This meter has high output power, with a starting action voltage measurement range of 10-2000V, leakage current measurement range of 0.1~199.9uA, good repeatability and stability, and one-key measurement for convenience and speed.
|
Measurement Function |
Output Voltage |
Measurement Range |
Accuracy |
Resolution |
|
Varistor |
Starting Action Voltage U1mA |
10~2000V |
±2%rdg±3dgt |
1V |
|
Leakage CurrentI0.75,1mA |
0.1~199.9uA |
±2%rdg±10dgt |
0.1uA |
|
|
Discharge Tube |
Discharge Voltage |
10~2000V |
±2%rdg±3dgt |
1V |
|
Insulation Resistance |
500V |
0~1000M |
±3%rdg±10dgt |
1M |
Function Varistor, discharge tube discharge voltage and leakage current measurement, insulation resistance test
Ambient Temperature & Humidity 23℃±5℃,75%rh or less
Power Supply DC 7.2V, 6 rechargeable batteries, continuous standby for more than 3 hours
Measurement Method DC voltage drop method
Range Shift Fully automatic range shift
Backlight Yes
Display Mode Color screen
LCD Size 108mm×65mm
Instrument Dimensions Length x Width x Height: 240mm×188mm×85mm
Test Leads Test leads: one red 1 meter, one black 1 meter, one green 1 meter
Measurement Stabilization Time ≤3 seconds
Overvoltage Protection Yes
Data Storage 500 groups, "H" storage indicator, "storage array" displays "500" to indicate storage is full
Data Review "MR" symbol indicates when reviewing data
Note: The above information and technical parameters are compiled and released by Yangzhou Dary Electric Co., Ltd.
.jpg)