SF6 Intelligent Micro Water Dew Point Meter



Features



Automatic zero calibration



Advanced probe protection function



Full-range curve tracking and correction



Simple operation and easy portability



Unique large-screen display



Anti-pollution and anti-interference



Exclusive large storage capacity



Good repeatability and fast response



*Curve display



High sensitivity and good stability



*Battery level display



Automatic conversion to standard value at 20°C



SF6 Intelligent Micro Water Dew Point Meter



Technical Parameters



Response time: For dew point between +20°C and -20°C, ≤1min;



Between -20°C and -40°C, ≤3min;



Between -40°C and -60°C, ≤8min;



Power supply: 220V AC/DC dual use, one charge lasts 8 hours



Operating environment: Temperature: -20°C to +60°C



Relative humidity: 0 to 95%



Pressure: ≤1.0Mpa



Dimensions and weight: Dimensions 300×220×130mm; Weight 4kg



Field Testing



Operation Steps



First, turn on the power and allow the instrument to perform automatic calibration for about five minutes;



First, connect one end of the inlet pipe to the instrument and close the flow control valve; then connect the other end of the inlet pipe to the equipment under test;



Open the flow control valve and adjust to about 0.6-0.7L/min;



The measurement will be completed automatically within a few minutes (measuring one sample takes about ten minutes, subsequent continuous measurements usually only take 2-5 minutes; if conversion is needed, refer to data conversion), press the save key to store data, and repeatedly press the display key to view historical data;



For continuous measurements, there is no need to turn off the instrument power; simply repeat the above steps, which can greatly save measurement time;



After using the instrument, be sure to turn off the power to protect the instrument battery;



Data Conversion



When the ambient temperature is higher than 20°C, if the measured value is greater than the standard value (the allowable moisture content of SF6 equipment at 20°C as specified by national standards), the measured value needs to be converted to the data at 20°C. The method is as follows:



When the measured gas temperature is stable, set the K value to +0.5 in the measurement parameter menu under the settings menu, and the value measured by the instrument will be the data at 20°C.



When the measured gas temperature is very unstable, wait until the value measured by the instrument stabilizes, then set the K value to +0.5; the value displayed by the instrument at this time will be the data at 20°C.



When the ambient temperature is lower than 20°C or when the measured value is lower than the standard value at ambient temperatures above 20°C, conversion is generally not required, and the K value should be 0 at this time.


WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us