DC High Voltage Generator LCD Display One-Key Boost 60KVPrecautions:
1. To ensure personal safety, users are repeatedly reminded to pay attention to the proper grounding of the control box and high-voltage tower, as well as the discharge of the test object and high-voltage tower after shutdown.
2. Do not block the upper and lower ventilation holes of the control box, and prevent foreign objects from falling in through the holes. If the control box has a fan, check regularly whether the fan is operating normally.
3. When the insulating cylinder of the high-voltage tower is dirty, wipe it clean with a dry cloth. Do not use alcohol, gasoline, or other organic solvents to clean it. You may use detergent to clean the surface of the insulating cylinder, and use it only after it has air-dried. When transporting or not in use, place it in the aluminum alloy case.
4. When replacing the fuse, replace it with the ampere rating indicated next to the fuse holder.
5. If the high-voltage shielded microammeter displays "LOW BAT", replace the 9V battery to avoid measurement errors. When not in use, turn off the power.
6. Do not open the control box and high-voltage tower without permission, as this will affect the product warranty. The manufacturer is not responsible for unauthorized disassembly.
DC High Voltage Generator LCD Display One-Key Boost 60KVApplications:
Suitable for DC withstand voltage and leakage tests of various high-voltage electrical equipment (except inductive loads) in power systems, especially for long cables.
The single-phase 50Hz AC power supply is rectified by a single-phase bridge rectifier with a bidirectional thyristor to obtain an adjustable DC voltage. After filtering, it enters a converter to produce medium-frequency AC, which is then boosted by a medium-frequency step-up pulse transformer and voltage-doubling rectifier to generate 60KV, 120KV, and 200KV DC high voltage. It is equipped with a low-voltage DC negative feedback circuit and a low-voltage DC overcurrent distribution circuit. The ZGF series medium-frequency DC high voltage generator has output voltages of 60KV with a current of 2mA, 120KV with a current of 2mA, and 200KV with a current of 2mA. It also features 0.75UI=1mA voltage and current display functions.
Working Principle Block Diagram

Product Specifications
|
Specification Technical Parameters |
60/2-10 |
120/2-10 |
200/2-10 |
250/2-5 |
200/300 3/2 |
Other Levels |
|
Output Voltage (kV) |
60 |
120 |
200 |
250 |
200/300 |