Instrument Transformer Performance Parameter Tester


Dary Electric recommends

Product Introduction
The Instrument Transformer Comprehensive Characteristic Tester is capable of testing excitation characteristics, transformation ratio, polarity, DC resistance of secondary winding, and AC load of CT secondary circuit for current transformers and voltage transformers.


The Instrument Transformer Comprehensive Characteristic Tester uses frequency conversion technology to test the excitation characteristics of current transformers with knee point voltage below 30KV.



★ Test the transformation ratio and polarity of current transformers (including CTs in transformer bushings).



★ Test the DC resistance of secondary winding and circuit load of current transformers.



★ Test the excitation characteristics, transformation ratio polarity, and DC resistance of secondary winding of voltage transformers.



★ Plot excitation curves and calculate knee point voltage/current, plot 5% and 10% error curves.



★ Measure ratio error and phase error. Determine remanence coefficient, excitation inductance, secondary time constant, transient area coefficient, peak value instantaneous error, accuracy limit factor, and instrument security factor.



★ Automatic wiring detection with alarm for wiring errors. Data can be transferred to PC via USB drive to generate Word format reports.





Main Technical Parameters



☆ Output voltage: AC 0~120V   Output current: 0~5A, peak 15A   Output power: 0~600VA



☆ Voltage measurement: 2~120V     AC load measurement: 0~1000VA, resolution 0.001VA   Standard: IEC60044-1 (GB1208-2006)



☆ Resistance measurement: 0~200Ω error ±(0.1%R+1mΩ) resolution 1mΩ IEC60044-6 (GB16847-1997)



☆ Current ratio error: ±0.1%   Current phase error: cosφ=0.8~1, 3min, resolution 0.1min 



Note: The above information and technical parameters are compiled and published by Yangzhou Dary Electric Co., Ltd.




WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us