Safety Warnings for Ultra-Low Frequency High Voltage Generator




The personnel using the ultra-low frequency high voltage generator must be professionals with a "High Voltage Test Work Permit".


       ● When using the ultra-low frequency high voltage generator, users must comply with Article 168 of the "Electric Power Safety Regulations" and install two obvious disconnection points before the working power enters the tester. When replacing test samples or wiring, first disconnect the two power disconnection points clearly.


       ● Before testing, please check whether all test wiring, control box, voltage doubling cylinder, and test sample grounding wires are properly connected. The test circuit grounding wire should be connected at a single point as shown in this manual (Figure 6).


       ● For discharging large capacitance test samples, use the ZS special discharge resistor rod to discharge the test sample. When discharging, do not immediately contact the test sample with the discharge rod; first gradually approach the test sample. When a certain distance is reached, air gap ionization discharge begins with a hissing sound. When no sound is heard, the discharge rod can be used for discharge, and finally directly connect the ground wire for discharge.


       ● When DC high voltage is 200kV or above, even if test personnel wear insulating shoes and are outside the safe distance area, due to the spatial electric field distribution of high-voltage DC ions, several nearby standing individuals may carry different DC potentials. Test personnel should not shake hands with each other or touch grounding bodies with their hands, otherwise slight electric shock may occur. This phenomenon is more obvious in dry areas and winter, but generally does not cause harm to the human body due to the small energy.


       ● The power supply for the ZS series portable ultra-light DC high voltage generator control box is AC 220V±10%, 50Hz. If the power supply is through a 1/1 isolation transformer or on-site self-generated power, one point of the power must be artificially connected to the earth.


 


 


 


 



Dear Customer:    


      Hello, our company is a high-quality development group with strong technical force, providing users with high-quality products, complete solutions, and excellent technical services. Our main products include high-voltage switch mechanical characteristics, insulation boot tester, transformer characteristic tester, lightning counter calibrator,,,, etc. Our enterprise adheres to the tenet of establishing business with integrity, maintaining business with quality, and prospering with enterprise, and continues to climb new peaks with a firmer pace, contributing to our national automation industry. Welcome new and old customers to confidently purchase their desired products. We will serve you wholeheartedly!