Total Phosphorus Online AnalyzerThe design principle complies with the method specified in the national standard GB11893-89, showing good correlation with manual laboratory analysis; it also meets the parameters specified in the industry standard HJ/T 103-2003. A proprietary algorithm is adopted to eliminate partial interference caused by color, suspended solids, and turbidity.
Total Phosphorus Online AnalyzerInstrument Features:
1.The unique design gives it a lower failure rate, lower maintenance requirements, lower reagent consumption, and higher cost-performance ratio compared to similar products.
2. Optical components: The dual-beam design, rarely used in domestic online monitoring instruments, is adopted. Detection is not affected by various environmental factors. The system automatically corrects systematic errors, improving measurement accuracy, stability, and repeatability.
3.Selection valve components: Imported original components from the United States, Japan, or Germany are used. These are internationally mainstream fluid components with smaller dead volume and simpler operation.
4.Metering components: Precise reagent metering is achieved through a visual photoelectric system, overcoming quantitative errors caused by wear of the peristaltic pump tube; it also enables precise metering of micro reagents, with each dose only1-5milliliters, greatly reducing reagent usage.

5. Sampling components: The peristaltic pump uses negative pressure suction, and there is always an air buffer between the reagent and the pump tube, avoiding corrosion of the pump tube.
6. Sealed digestion components: The high-temperature and high-pressure digestion system accelerates the reaction process and overcomes equipment corrosion caused by volatile corrosive gases in open systems.
7. Reagent tubes: Imported modified polytetrafluoroethylene transparent hoses are used, with a diameter greater than1.5mm, reducing the probability of blockage by sample particles.
8. Signal processing: The instrument uses an original imported high-precision analog-to-digital conversion chip, greatly enhancing the scalability of the core board, adapting to various usage environments, and making the instrument easier and more user-friendly to operate.9. Temperature control: Imported temperature sensing elements form a precise temperature control system, and temperature compensation technology is adopted to overcome the influence of temperature drift, ensuring that the sample reaction conditions better meet requirements.
(Installation cases of some customers using the Total Phosphorus Online Analyzer)