Desktop|中文
Home About Us Products + News Center Technical Articles Messages Contact Us

Product Details

全自动Dielectric Loss Tester-扬州达瑞

Triple Frequency Induction Voltage Generator - Yangzhou Dary

Published: 2020-08-21 16:10:18

Views: 2922

Category: Triple Frequency Generator

Product Description
Triple Frequency Induction Voltage Generator

 

Dary Electric recommends

Product Introduction

We can provide complete sets of products including control equipment and chassis. This generator is one of the basic equipment for performing multiple-frequency induction high-voltage tests on small-capacity power transformers and cascade high-voltage voltage transformers in power systems, power plants, substations, and power distribution networks. It can also be used for multiple-frequency and multiple-voltage tests on various low-voltage electronic and instrument transformers, inductor coils, and electrical appliance coils. Additionally, it can serve as a multiple-frequency power source with a power not exceeding 1 kilowatt for power supply or testing of certain special electrical equipment.


This product is a static frequency conversion device with low noise and small size. It can completely replace traditional frequency conversion units in high-voltage systems.

Working Principle


Three single-phase transformers have their primary windings connected in a star configuration and secondary windings connected in an open delta. When a symmetrical three-phase sinusoidal power supply is applied to the primary side, and the voltage is raised to saturate the iron core magnetic circuit, the content of the third harmonic component in the magnetic flux increases, correspondingly increasing the third harmonic voltage induced in the iron core coils.

The 150 Hz (triple power frequency) induced voltage output from the secondary side of the open delta generator serves as the triple frequency test power supply voltage.When the triple frequency generator is loaded with a load (for example, a YHJC—220 high-voltage cascade voltage transformer), its current changes from inductive to capacitive. Due to the low power factor, the efficiency of the generator is relatively low, generally only about 20%. Therefore, a reactor can be connected to an empty winding of the test object for current compensation to improve the power factor of the entire test circuit.




Note: The above information and technical parameters are compiled and published by Yangzhou Dary Electric Co., Ltd.







WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us