全自动Dielectric Loss Tester-扬州达瑞

Triple Frequency Induced Withstand Voltage Test Set

Published: 2017-07-03 16:50:52

Views: 2922

Category: Triple Frequency Generator

Product Description

Product Features: 


This product, the triple frequency power generator, triple frequency voltage generator, and triple frequency high voltage generator, is designed to meet the requirements of <>, <> and >—1995 for triple frequency induced withstand voltage tests and partial discharge tests.


The induced withstand voltage test for transformers and instrument transformers is an important test to verify whether the product meets national standards. The longitudinal insulation induction test of interlayer, inter-turn, segment, and interphase insulation of windings is an important item to verify whether the windings meet requirements. To increase the test voltage of the windings without saturating the transformer or instrument transformer core excessively, which would lead to excessive excitation current, the test frequency needs to be increased, generally to 100Hz—400Hz.


There are multiple methods to obtain a 100Hz—400Hz power supply, among which the most applicable are:


① Combination of three variable frequency generators (100Hz—400Hz);


② Combination of three single-phase transformers (150Hz), and the most convenient is the second method.


The combination method of three single-phase transformers: the primary side is star-connected, and the secondary side is open delta. When the core is not saturated, the main magnetic flux it produces must be a flat-topped wave. Since the flat-topped main magnetic flux contains a significant component of third harmonic magnetic energy Φ3, and the third harmonic magnetic flux frequency f3=3f1, the main magnetic flux induces a third harmonic phase electromotive force.


Since the primary side is star-connected and the secondary side is open delta-connected, the core operates in a saturated state, and the no-load current I is a peaked wave. In addition to the fundamental wave, it also contains higher harmonics. Among the higher harmonics, the amplitude of I is relatively large. Due to the open secondary, the three-phase fundamental components cancel each other out, leaving only the third harmonic output.


The entire machine's voltage output is achieved by tuning to produce resonance under a 150Hz power supply. When the voltage increases, a certain squealing sound during resonance is normal.




Technical Parameters:


Rated capacity: 5-100kVA


Input: three-phase 380V, 50Hz sine wave


Output: 0-300V, 0-500V, 0-1000V (custom voltage available), 150Hz,


Waveform distortion ≤1%


Capacity: 3-150kVA


No-load operation time: ≤5 minutes


Load operation time: 40-60 seconds

WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us