Steel Bar Gauge Marker DR2136
1. First, determine the gauge length. To adjust the gauge length, loosen the fixing screws on both sides of the printing assembly by 5 mm, then tighten the screws again.
2. Lift the cone rod lifting handle, straighten the steel bar and place it into the V-shaped groove (with the straight edge of the rebar facing up), then tighten it securely.
3. Lower the handle and rotate the small wheel at the left end so that the cone rod is in position. Adjust the height adjustment handle so that the cone tip touches the steel bar, then continue to lower it by 1-2 mm to ensure sufficient penetration allowance for the cone head.
4. Lift the handle, connect the power supply, switch the direction switch to the left travel position, and turn on the power switch. The power indicator light will illuminate. If the printing assembly is in the middle position, the working indicator light will also illuminate. When the printing assembly travels to the left end and stops automatically, the working indicator light will turn off.
5. Lower the cone rod, switch the direction switch to the right travel position, press the right travel button, and wait for the motor to run normally. Release the button, and the printing assembly will travel to the right end and stop automatically.
6. Lift the cone rod, loosen the fixing screws, remove the steel bar, and the marking is complete.
7. Then switch the direction switch to the left travel position, press the left travel button, and after the motor runs, release the button. The printing assembly will travel to the left end and stop automatically, maintaining readiness for the next operation.
Steel Bar Gauge Marker DR2136
1. Power input voltage: 220V ±10;
Steel Bar Gauge Marker Album (2 photos)
2. Input current: 0.2A;
3. Marking gauge length: 5mm 10mm;
4. Dimensions: 630×230×300mm;
5. Weight: approximately 30 kg.
1. Power input voltage: 220V ±10;
1. Ensure reliable grounding before using the steel bar gauge marker.
2. When moving left, the cone rod must be lifted, and the operation must strictly follow the instructions. Incorrect operation will damage the motor and electrical components.
3. Keep the instrument clean and store it in a dry place.
4. Regularly apply lubricating oil to the sliding parts of the steel bar gauge marker.