Desktop|中文
Home About Us Products + News Center Technical Articles Messages Contact Us

Product Details

全自动Dielectric Loss Tester-扬州达瑞

UPS Fake Load Test - Yangzhou Darui

Published: 2020-08-22 15:50:55

Views: 2922

Category: Battery Charge-Discharge Tester

Product Description
UPS Fake Load Test



Darui Electric recommends for you:



UPS test fake load. Various diesel generator sets and UPS (uninterruptible power supply) are used as emergency backup power sources after mains failure or power outage. Most of the time, diesel generator sets and UPS (uninterruptible power supply) are in standby mode. Once a power outage occurs, the diesel generator set is required to start and supply power immediately; otherwise, the backup diesel generator set will lose its significance. Practice has proven that strengthening daily inspection and maintenance of diesel generator sets can effectively avoid accidents. Only by establishing a comprehensive inspection and maintenance procedure for diesel generator sets, and regularly performing maintenance, upkeep, and inspection in a standardized manner, can problems be prevented before they occur. According to a new survey of many grassroots maintenance personnel, a common technical difficulty in current power maintenance work is that the output power and various electrical characteristic parameters of various diesel generator sets and UPS equipment cannot be effectively and smoothly tested due to the lack of high-power AC fake loads. Only after a power supply failure occurs do people realize that the performance of the diesel generator set or UPS (uninterruptible power supply) has problems. The JZC intelligent AC fake load is the third-generation product of our company's AC fake load equipment. It is mainly used in power, communication industries and manufacturers for testing, acceptance, and aging of high-power UPS, diesel generator sets, and inverters. The JZC intelligent AC fake load provides a testing method for diesel generator sets, with high working stability, simple operation, reasonable structure, and easy portability; the application of intelligent technology makes this equipment excellent in quality, performance, and function, becoming a leading product among high-power AC intelligent fake load devices, providing a scientific testing method for high-power AC power equipment. After technical novelty search and appraisal, the working performance and various technical indicators of the JZC intelligent AC fake load are at the leading level both domestically and internationally. Purpose of AC fake load for diesel generator set testing and maintenance: Test diesel generator sets: unbalanced load capability; steady-state voltage regulation rate; steady-state frequency regulation rate; transient voltage regulation rate; transient frequency regulation rate; voltage recovery time; frequency recovery time; continuous operation test of diesel generator set. Note: Electrical characteristics are automatically tested, and data is calculated by the load's own computer. Test UPS: output voltage regulation accuracy; output voltage unbalance; dynamic voltage transient range; overload capability; mains-battery transfer time; bypass-inverter transfer time; backup time. Note: Electrical characteristics are automatically tested, and data is calculated by the equipment's own computer. Main functions of AC fake load for diesel generator set testing and maintenance: shutdown protection function, intelligent control and data processing function, query function, online communication, parallel function: Main features of AC fake load for diesel generator set testing and maintenance: safety, high intelligence, high detection data accuracy, precise power control (constant power), multifunctional integrated LCD display, multi-CPU working mode, excellent power dissipation components, portability, complete heat dissipation system



Parameters of various intelligent models: Model JZC-100 JZC-200 JZC-300 JZC-500 JZC-800 Access load voltage 400V 400V 400V 400V 400V Discharge power setting 0-100KW 0-200KW 0-300KW 0-500KW 0-800KW Discharge duration setting 0-99H59M 0-99H59M 0-99H59M 0-99H59M 0-99H59M Discharge control accuracy 1% 1% 1% 1% 1% Voltage measurement accuracy 1% 1% 1% 1% 1% Frequency measurement accuracy ±2% ±2% ±2% ±2% ±2% Power control accuracy ±2% ±2% ±2% ±2% ±2% Power measurement error ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% Voltage measurement error ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% Frequency measurement error ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% Current measurement error ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% Power resolution 0.1KW 0.1KW 0.1KW 0.1KW 0.1KW Voltage resolution 0.1V 0.1V 0.1V 0.1V 0.1V Frequency resolution 0.1Hz 0.1Hz 0.1Hz 0.1Hz 0.1Hz Current resolution 0.1A 0.1A 0.1A 0.1A 0.1A Minimum power step 0.1KW 0.1KW 0.1KW 0.1KW 0.1KW Heat dissipation form Forced air cooling Forced air cooling Forced air cooling Forced air cooling Forced air cooling Working power supply AC220 AC220 AC220 AC220 AC220



Note: The above information and technical parameters are compiled and released by Yangzhou Darui Electric Co., Ltd.





WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us