Desktop|中文
Home About Us Products + News Center Technical Articles Messages Contact Us

Product Details

全自动Dielectric Loss Tester-扬州达瑞

Single-Chip Microcomputer Relay Protection Tester - Yangzhou DARUI

Published: 2020-08-22 14:57:32

Views: 2922

Category: Microcomputer Relay Protection Tester

Product Description
Single-Chip Microcomputer Relay Protection Tester



DARUI Electric recommends



Technical Parameters:

1. AC Current Source:

    Phase current output (RMS): 0--40A/phase, Accuracy: 0.2%

    Three-phase parallel output (RMS): 0--120A/three-phase in-phase parallel output

    Phase current long-term allowable working value (RMS): 10A

    Maximum output power per phase: 420VA

    Maximum output power of three-phase parallel current: 900VA

    Maximum allowable working time for three-phase parallel current output: 10s

    Frequency range: 0--1000Hz, Accuracy: 0.001Hz

    Harmonic order: 2--20 times, Phase: 0--360°, Accuracy: 0.1°

2. DC Current Source:

    Current output: 0--±20A/phase, Accuracy: 0.2%

3. AC Voltage Source:

    Phase voltage output (RMS): 0--125V/phase, Accuracy: 0.2%

    Line voltage output (RMS): 0--250V

    Phase voltage/line voltage output power: 75VA/100VA

    Frequency range: 0--1000Hz, Accuracy: 0.001Hz

    Harmonic order: 2--20 times, Phase: 0--360°, Accuracy: 0.1°

4. DC Voltage Source:

    Phase voltage output amplitude: 0--±150V, Accuracy: 0.2%

    Line voltage output amplitude: 0--±300V

    Phase voltage/line voltage output power: 90VA/180VA

5. Switching Quantity Terminals:

    Switching quantity input terminals: 8 pairs

    Dry contacts: 1--20mA, 110V device internal active output

    Potential flip: 0--6VDC is low level

            15--250VDC is high level

    Switching quantity output terminals: 4 pairs, dry contacts, Breaking capacity: 110V/2A, 220V/1A.

6. Time Measurement Range:

    Range: 1ms--9999s, Measurement accuracy: 1ms

7. Dimensions and Weight:

    Dimensions: 365(mm) × 400(mm) × 195 (mm), Weight: 18Kg

8. Power Supply: AC220V±10%, 50Hz, 10A



Main Features:

1. Meets all on-site test requirements. It can test various traditional relays and protection devices, as well as various modern microcomputer protections. Especially for transformer differential protection and standby power supply automatic switching devices, testing is more convenient and accurate.


It has standard four-phase voltage and three-phase current simultaneous output, voltage 125V/phase, current 40A/phase. Three-phase current parallel can reach 120A.

2. All technical indicators fully meet the standard of DL/T624-1997 "Technical Conditions for Microcomputer Test Devices for Relay Protection" issued by the Ministry of Electric Power.

3. Stand-alone operation, built-in high-performance industrial computer, main frequency 300--600MHz, memory 512M, hard disk 4--12G, running Windows XP operating system.

4. In the same industry domestically, it is the first to adopt imported brushed stainless steel panel and stainless steel keyboard, and uses touch mouse, overcoming the disadvantages of trackball mouse being inflexible and easily damaged. It also uses an 8.4-inch TFT true color display with a resolution of 800×600, making the overall operation convenient and durable.

5. The main control board adopts DSP+FPGA structure, 16-bit DAC output, which can generate high-density sine waves of 2000 points per cycle for the fundamental wave, greatly improving waveform quality and test accuracy.

6. The power amplifier adopts high-fidelity linear power amplifier, which ensures both the accuracy of small currents and the stability of large currents.

7. It uses USB interface to directly communicate with PC, no need for any conversion cables, convenient to use.

8. It can be connected to a laptop for operation. The laptop and the industrial computer use the same software, no need to relearn operating methods.

9. It has GPS synchronization test function. The device can be built-in GPS synchronization card (optional) connected to PC via RS232 port, enabling two testers to conduct synchronous adjustment tests in different locations.

10. It is equipped with an independent dedicated DC auxiliary voltage source output, with output voltages of 110V (1A) and 220V (0.6A) respectively, to provide DC working power for relays or protection devices that need it.

11. It has software self-calibration function, avoiding the need to open the chassis to adjust potentiometers for calibration, thus greatly improving the stability of accuracy.



Note: The above information and technical parameters are compiled and released by Yangzhou DARUI Electric Co., Ltd.




WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy